R1C-4 it’s a dedicated control unit for the Rebel- S family

  • It manages 4 axes
  • No batteries (no UPS)
  • No BCM for overloads or short circuit
  • Instead, a fuse covers this function for the
    24V directed outside

Two states of functioning have been identified: R1C-4 ​can be
used with VirtualTP5 or normalTP5.

The R1C-4 allowed digital interaction with the robot through a PC interface without interrupting the normal functioning of the robot itself.
This modality of functioning allows:

  • The visualization of the interface of TP5 on a PC and the interaction with it
  • The movement of the robot (JOG),the starting of the DRIVEs, the START/STOP of the cycle also with open gates (and with an operator inside the cell).

Specyfikacja tehniczna: RC1-4

Dimensions
Height x Width x Depth (basic version without options)
266 x 427 x 498 mm 10.47 x 16.81 x 19.60 in
Weight
Control Unit (standard version) The weight indicated may differ minimally depending on the configuration. Always refer to the nameplate posted on the Control Unit
23 kg / 50 lb without packaging
Power Supply Data
Power supply voltage (according to EN 60204-1 § 4.3.3 standard, voltage interruption not exceeding 20 ms)
230 Vac ± 10%
Frequency (according to EN 60204-1 § 4.3.3 standard)
50 to 60 Hz (±2 Hz)
Main switch rated current
16 A to 250 Vac
Note: the supply disconnecting device is a switch-disconnector
Power installed
3 KW
Auxiliary circuits voltage
24 Vdc
Environment Conditions
Cabinet protection (according to EN 60529 standard)
IP 2x
Environment temperature without cooling systems Test conditions according to EN 60068-2-14 standard)
from +5 °C to +45 °C from +41 °F to 113 °F
Environment storage temperature (according to EN 60204-1 § 4.5 standard)
from -25 °C to +55 °C from -13 °F to 131 °F  +70 °C / 158 °F for periods shorter than one hour.
Maximum temperature gradient
1,5 °C/minute 2,7 °F/minute
Relative humidity (according to EN 60204-1 § 4.4.4, test conditions HD 323.2.3. S2)
from 5% to 95% without condensate
Altitude of the installation site (according to EN 60204-1 § 4.4.5 standard)
from 0 to 1.000 m / 0 to 3280 ft above sea level
Controllable Axes
Total of the system
up to 4 axes
Cooling
Cabin
Forced air recirculation (with exhaust fan)
Drive command
Forced air recirculation
Vibrations and Shocks During Transportation
Sinusoidal vibration (according to EN 60068-2-64 standard)
Frequency 10 - 250 Hz 0.6 g rms axis Z acceleration 0.2 g rms axes X-Y acceleration
Installation Requirements
Installation position
Inside the RACK cabinet
Internal minimum dimensions of the RACK cabinet (width x depth x height)
483 x 600 x 265.9 mm 19 x 23.62 x 10.47 in
Space occupied on RACK cabinet
6 Units
Number of RACK Units to be placed between 2 Control Units in case of simultaneous installation in the same cabinet
Minimum 1 Unit

Write us

* field required

invalid field
invalid field
invalid field
According to Russia Federal Law 242FZ, Russian citizens data will be managed only in Russia invalid field
invalid field
invalid field
invalid field
invalid field
invalid field
invalid field



invalid field

Call us

invalid field

Write us

* field required

invalid field
invalid field
invalid field
invalid field
invalid field
invalid field
invalid field
invalid field
According to Russia Federal Law 242FZ, Russian citizens data will be managed only in Russia invalid field
invalid field
invalid field



invalid field

​​