All your needs under control

Fast processing, modular system for drive units, I/O and fieldbus, free and ergonomic space for application functions integration, compact dimensions. All you need under control.

High processing power

The CG5 uses the latest generation of industrial PC’s APC820 with Core2 Duo technology CPU which is capable of obtaining high performances with low energetic consumption.

Energy saving

  • Lowest consumption in stand by, low consumption during operations
  • Cooling system proportional to control unit’s operations
  • Energy network recover system with a high dynamic content program

Flexibility and reliability

The new generation of field busses based on Hilscher technology, integrated by B&R in their remote I/O X20 family, guarantees a flexible and reliable interface in every customer application. Modular interfaces are available, such as digital I/O, analog I/O and for many kinds of position transducer encoder, resolver, etc.

RobotSAFE

Safe robot controller models allow a safety rated management of the robot motion (joint or cartesian mode) and speed through sensors, offering advanatges in terms of smaller layouts and absence of physical fences. We provide the safety of your automatic cell without affecting your productivity.

Modularity /expandibility

Modular system for drives up to 13 axes in the base cabinet function of the power, and the robot model.

Case and cable

  • 65% smaller than the standard version, lighter and easier to integrate
  • Power saving, 50% less installed power than the standard version
  • Runs up to 8 axes depending on the robot model
  • Also available in safe version
  • Also available in open controller version

Main technical data

  • Dimensions: 550x500x550 mm
  • Working temperature: 5 to 45°C
  • Humidity: 90% max, no condensation
  • Extended line power range: 400 to 500V

Technical specifications: C5Compact 0.5 / 0.75

Dimensions
Height x Width x Depth (basic version without options)
554 x 530 x 500 mm / 21.81 x 20.87 x 19.68 in
Note:
Change the installation height of the cabinet (and consequently the cut-off and control devices) in accordance with the applicable electrical standards.
Weight
Control unit (standard version)
The weight indicated may differ depending on the configuration. Always refer to the plate posted on the Control Unit
100 kg / 220 lb without packaging
Power supply data
Power supply voltage
(according to EN 60204-1 § 4.3.3 standard, voltage interruption not exceeding 20 ms)
from 400 Vac -10% to 480 Vac +10%
Frequency (according to EN 60204-1 § 4.3.3 standard)
50 a 60 Hz (±2 Hz)
Main switch interruption power
Standard Models 6 kA a 500 Vac North America Models 8 kA a 500 Vac
Note:
On C5Compact the sectioning device is a pure isolating switch
Power installed
from 4 to 6 kVA
Auxiliary circuits power
24 Vdc
Environment conditions
Cabinet protection (rear compartment excluded) (according to EN 60529 standard)
IP 54 / NEMA 12
Rear compartment protection (according to EN 60529 standard)
IP 2x
Environment temperature without cooling systems Test conditions according to EN 60068-2-14 standard)
from +5 °C to +45 °C *2 / from +41 °F a 113 °F
Environment temperature with cooling systems Test conditions according to EN 60068-2-14 standard)
from +5 °C to +55 °C *2 / from +41 °F a 131 °F
Environment storage temperature (according to EN 60204-1 § 4.5 standard)
from -25 °C a +55 °C / from -13 °F a 131 °F - +70 °C / 158 °F for periods shorter one hour.
Maximum temperature gradient
1,5 °C/minute / 2,7 °F/minute
Relative humidity (according to EN 60204-1 § 4.4.4, test conditions HD 323.2.3. S2)
from 5% to 95% without condensation
Altitude of the installation site (according to EN 60204-1 § 4.4.5 standard)
from 0 a 1.000 m / 0 to 3280 ft above mean sea level
Axis controlling capability
Total for the system
up to 8 axes (6 basic axes, 1 additional module from 11 A, or 1 additional module double up to 5.5 A) / 6 axes
Cooling
Standard cabin model
Natural convention
Drive command
Forced air recirculation
Vibrations and crashes
Sine vibration (according to EN 60068-2-64 standard)
Frequency 10 - 250 Hz 0.6 g rms axis Z acceleration 0.2 g rms axes X-Y acceleration

Write us

* field required

invalid field
invalid field
invalid field
According to Russia Federal Law 242FZ, Russian citizens data will be managed only in Russia invalid field
invalid field
invalid field
invalid field
invalid field
invalid field
invalid field



invalid field

Call us

invalid field

Write us

* field required

invalid field
invalid field
invalid field
invalid field
invalid field
invalid field
invalid field
invalid field
According to Russia Federal Law 242FZ, Russian citizens data will be managed only in Russia invalid field
invalid field
invalid field



invalid field

8​